Pipe Bedding Calculator
Contact Us
Pipe Bedding Calculator
Work out the granular or concrete volumes — bed, haunch and surround — for a buried pipe by bedding class, with tonnage and waste allowance. Geometry to the traditional UK bedding classes (F, B, S, A, Z); installation to BS EN 1610:2015.
Granular bed, haunch & surround
Pea gravel or single-size aggregate around the pipe. Pick a bedding class (or set a custom height) — the pipe displacement is removed using exact circular geometry.
Concrete bed, cradle & surround
For Class A (concrete cradle) and Class Z (full concrete surround/encasement), used where extra structural support is needed.
Reference & bedding classes
The geometry and typical bedding factors for each class. Class letters and details vary by specifier — confirm against BS EN 1610, the pipe manufacturer and (for adoptable works) the water company's DCG.
| Class | Material | Geometry | Bedding factor* |
|---|---|---|---|
| D | none | pipe on trimmed trench bottom | ~1.1 |
| N / F | granular | granular bed under barrel only | ~1.5 |
| B | granular | bed + haunch to pipe centreline | ~1.9 |
| S | granular | full granular surround to above crown | ~2.2 |
| A | concrete | concrete cradle (120–180°) | ~2.6–3.4 |
| Z | concrete | full concrete surround / encasement | high |
*Bedding factor is the load-carrying improvement over a pipe on the bare trench bottom — higher means the pipe can take more load for a given strength. Values are typical/indicative; use the figures from the pipe manufacturer's structural design.
Materials. Granular bedding is typically 10 mm single-size or pea gravel (≈1.5–1.7 t/m³). Bedding thickness is normally 100 mm minimum (150 mm in rock or soft ground). Granular surround usually extends 100–150 mm above the crown; concrete surround 150 mm all round.
Geometry used here. Bed = trench width × bed depth. Haunch/surround = trench width × zone height, minus the pipe cross-section within that zone (computed with exact circular-segment maths). Volumes are for ordering; check against the constructed detail and BS EN 1610.
This pipe bedding calculator works out the granular or concrete volumes — bed, haunch and surround — for a buried pipe by bedding class, with tonnage and a waste allowance. The geometry follows the traditional UK bedding classes (F, B, S, A and Z) and installation to BS EN 1610:2015. For the wider Building Regulations context, see Approved Document H.
Granular bed, haunch and surround
Pick a bedding class — Class F is a bed only, Class B is bed plus haunch to the pipe centreline, and Class S is a full granular surround — or set a custom height. Enter the trench width, pipe outside diameter and the bed and cover depths, and the calculator removes the pipe displacement using exact circular geometry so the aggregate volume is accurate, not a rough rectangle.
Concrete bed, cradle and surround
For concrete protection the calculator does the same for a concrete bed, cradle or surround, which is what you need where cover is shallow or loads are high.
Tonnage and waste
The calculator converts the volume to tonnes using the material density and adds a waste allowance, giving you a figure you can order to.
Further reading: drainage information needed for planning permission · the Approved Documents.
Frequently asked questions
Class F is a granular bed only; Class B adds haunch up to the pipe centreline; Class S is a full granular surround. The class is chosen for the pipe, the cover and the ground.
It depends on the trench width, pipe diameter and class. The calculator removes the pipe volume from the trench and gives the aggregate volume and tonnage.
Typically 100 mm of granular bed below the barrel, or 150 mm in rock. The calculator lets you set this and includes it in the volume.