Septic Tank Size Calculator

Contact Us
Line drawing of houses, trees, and a cloud in the background, with a river in front. In the foreground are a pair of compasses and a set square, symbolising architecture or urban planning.

Septic Tank Size Calculator

Work out the minimum septic tank capacity for a property from the number of users or bedrooms, plus the daily wastewater flow and organic load. Built on UK Building Regulations (Approved Document H2) and British Water Flows & Loads / BS 6297.

Minimum septic tank capacity

Approved Document H2 (1.18): at least 2,700 litres for up to 4 users, plus 180 litres for each additional user. Cross-checked against the British Water / BS 6297 formula.

Minimum capacity (Approved Document H)

Daily flow & organic load

The figures you need for a discharge/permit assessment: hydraulic flow at 150 litres per person per day and organic load at 60 g BOD per person per day (British Water Flows & Loads).

Daily wastewater flow

A septic tank only settles solids — it must discharge to a drainage field for secondary treatment (it cannot discharge directly to a watercourse). Drainage field floor area At = p × Vp × 0.25 (m²), where p = population and Vp = the percolation value from a soil test.

Reference & rules

The sizing bases and the key compliance points for off-mains foul drainage.

Minimum capacity by users (Approved Document H 1.18)
UsersAD H min. capacityBS 6297 (150P+2000)

Sizing bases. Approved Document H: 2,700 L for ≤4 users, +180 L per extra user. British Water / BS 6297: capacity = 150 × population + 2,000 L, minimum 2,700 L (assumes annual de-sludging). The larger figure governs.

Population. Single dwelling = bedrooms + 2, minimum 5 people. Size for maximum occupancy, not current residents; children count as adults.

Compliance. A septic tank must discharge to a drainage field/soakaway, never directly to a watercourse (England & Wales General Binding Rules). It needs two chambers, ventilation, and at least annual emptying by a licensed contractor. Install ≥7 m from a habitable building where possible and keep clear of water supplies. A percolation test and drainage-field design are required.

Disclaimer. This calculator is a free guidance tool based on Approved Document H2 (2015) and British Water Flows & Loads / BS 6297. It gives a minimum capacity only and does not cover drainage-field design, ground conditions, discharge permitting or the General Binding Rules in detail, and is not a substitute for a design checked by a qualified engineer. Use at your own risk; always confirm against current regulations, the Environment Agency / NRW and your local authority.

This septic tank size calculator works out the minimum septic tank capacity for a property from the number of users or bedrooms, plus the daily wastewater flow and organic load. It follows Approved Document H2 and the British Water Flows & Loads / BS 6297 method. The rules for using a septic tank without a permit are the Environment Agency's general binding rules.

Minimum septic tank capacity

Approved Document H2 sets a minimum of 2,700 litres for up to four users, plus 180 litres for each additional user, cross-checked against the British Water / BS 6297 formula. Enter the design population directly, or estimate it from bedrooms (population = bedrooms + 2, minimum 5). The calculator returns the minimum capacity.

Daily flow and organic load

For a discharge or permit assessment you also need the hydraulic flow (150 litres per person per day) and the organic load. The calculator gives both, so you have the figures the Environment Agency or your designer will ask for.

After the tank — the drainage field

A septic tank only settles and partially treats the effluent; it then has to discharge to a drainage field sized from a percolation test. Use our drainage field calculator for that, and check whether you need a percolation (infiltration) test first.

Frequently asked questions

At least 2,700 litres for up to four people, plus 180 litres per extra person, under Approved Document H2. The calculator confirms the figure from your population or bedrooms.

Not if you meet the Environment Agency's general binding rules. If you cannot, you need an environmental permit. The rules also require discharge to a drainage field, not a watercourse.

British Water Flows & Loads takes population as bedrooms plus two, with a minimum of five. The calculator uses this when you size by bedrooms.

Get a no-obligation, free quote

One of our experienced Flood Risk Consultants will get back to you within 60 minutes

Get a Quote

Get a no-obligation, free quote

If you need a quote or to discuss your requirements in more detail contact Jackie Stone, one of our experienced Flood Risk Consultants.

Call +44 (0) 1293 214444, email enquiries@unda.co.uk or fill in the form below

"*" indicates required fields

This field is for validation purposes and should be left unchanged.