Wandsworth Council decides flood risk and drainage on Policy LP12 (Water and Flooding) of the Wandsworth Local Plan 2023-2038, adopted on 19 July 2023, read with the London Plan 2021. LP12's distinctive rule is a shortcut with a catch: across the borough's growth areas the Sequential Test counts as passed, yet the scheme must still meet the Exception Test on site, and in tidal Flood Zone 3a a basement bedroom is refused wherever the SFRA maps moderate, significant or extreme breach hazard.

As a London borough, Wandsworth holds both roles: it is the local planning authority that decides the application and the Lead Local Flood Authority that reviews the drainage behind it. About a quarter of the borough lies in the higher-risk flood zones (Local Plan para 15.37), much of it along the Thames at Battersea, Nine Elms and the Wandle Delta behind the river walls, so the risk the council asks about there is what happens if a defence is breached or overtopped. On drainage, LP12 asks every scheme to bring surface water down to greenfield runoff, or at least to cut the existing peak by half. We prepare flood risk assessments and drainage strategies for applications to Wandsworth Council, and this page sets out what each requirement asks for and how our reports answer it.

Drainage first: what Wandsworth asks of surface water on every scheme

Wandsworth's drainage standard is written into the Local Plan rather than a separate design guide. LP12 part G requires SuDS "in all development proposals", and the first test is "A reduction in surface water discharge to greenfield run-off rates will be achieved unless it is clearly demonstrated that this is technically unfeasible" (Wandsworth Local Plan 2023-2038, July 2023). Where greenfield is shown to be out of reach, the fallback is "at least a 50% attenuation", with the aim of 100% attenuation of the site's existing peak runoff.

  • Greenfield or half. LP12 G1 and G2: greenfield runoff unless it is technically unfeasible, then at least 50% attenuation of the existing peak, aiming for 100%. The supporting text (para 15.47) asks applicants to show every opportunity to get as close to greenfield as is practical.
  • The London hierarchy, in order. Paragraph 15.45 applies the London Plan drainage hierarchy to every scheme that changes runoff: store rainwater for use, infiltrate, attenuate in open features, attenuate in tanks, discharge to a watercourse, then a surface water drain, with the combined sewer last.
  • Never to the foul sewer. LP12 part I: surface water goes to the ground, a watercourse or a surface water sewer, not the foul sewer. The July 2026 validation checklist repeats that surface water is normally not permitted to join the public foul system.
  • Proof of sewer capacity. If surface water is to reach a public sewer, paragraph 15.46 asks for written confirmation that the network has capacity for the development.
  • Major schemes. LP12 Table 15.1 requires "A sustainable Drainage Statement" for all major development, and the council's drainage page for developers (updated 13 April 2023) says the Lead Local Flood Authority has been consulted on every major application since 15 April 2015, pointing applicants to the London Sustainable Drainage Proforma.
  • Minor schemes. LP12 G3 asks minor development not to affect floodplain storage or flow routes, using mitigation in line with CIRIA's SuDS guidance.
  • Basements under gardens. Policy LP6 asks for at least one metre of naturally draining soil and a 200 mm drainage layer over any basement beneath a garden, so rain still soaks in above it.

Infiltration is the second step of the hierarchy, but most of the borough sits on London Clay and the Local Plan's own wording limits porous surfaces to "non-clay areas". A drainage statement in Wandsworth therefore has to show why infiltration does or does not work on the particular site, normally with ground investigation and testing to BRE 365. Our BRE 365 infiltration rate calculator and the ground conditions and soakaway map show where to start.

Climate change is applied to rainfall using the Environment Agency's peak rainfall intensity allowances (last updated 27 May 2022); Wandsworth does not publish its own figure. We found no council statement adopting the 2025 National Standards for sustainable drainage, and the council's own LLFA page says its Sustainable Drainage Approving Body duty has not commenced, so drainage is secured through planning conditions and, under LP12 part H, Section 106 contributions set by the Planning Obligations SPD adopted on 1 December 2025. Our notes on the London SuDS proforma and the 2025 National Standards explain both.

Planning officer, drainage reviewer and the Environment Agency: who decides what in Wandsworth

There is no county tier in London and no internal drainage board, so three public bodies and the sewerage company shape a Wandsworth decision.

BodyRoleWhat it decides or is consulted on
Wandsworth CouncilLocal planning authorityDecides the application against LP12, LP6, LP58, the London Plan and Chapter 18 of the NPPF; validates it against the July 2026 Local Validation Checklist; confirms whether a site lies in an SFRA breach hazard area
Wandsworth CouncilLead Local Flood AuthorityConsulted on surface water drainage for major development; consents works on ordinary watercourses; holds the Surface Water Management Plan (December 2021) and the Local Flood Risk Management Strategy (August 2023)
Environment AgencyStatutory consulteeRiver and tidal flood risk on the Thames, Wandle, Beverley Brook and Graveney; works within 20 m of a main river bank (LP12 para 15.53); advises the extreme water level used for floor levels in defended tidal areas; any departure from the 16 m and 8 m set-backs must be agreed with it
Thames WaterSewerage undertakerWritten confirmation of capacity before surface water joins a public sewer (LP12 para 15.46); foul connections
Mayor of LondonStrategic planning authorityLondon Plan Policies SI 12 and SI 13; referable applications

The split matters in practice. A riverside scheme can satisfy the Environment Agency on tidal flood levels and still draw an objection from the council's drainage officers if its runoff does not meet LP12 part G. Our explainers on the Lead Local Flood Authority and on how planning authorities handle flood risk and SuDS describe each role.

Policy LP12 and the other flood policies Wandsworth applies

Applications are read against the Wandsworth Local Plan 2023-2038 and the London Plan 2021. The Local Plan Partial Review, adopted on 4 March 2026, replaced six housing policies only (LP23, LP24 and LP28 to LP31), so every flood and drainage policy in the 2023 plan still applies as written.

PolicyTitleWhat it requiresYour obligationHow Unda meets itSource and date
Policy LP12Water and FloodingAll sources assessed with climate change; Sequential Test (passed in Area Strategy areas and on allocations) and Exception Test; floor levels and Low Hazard access by zone; Flood Emergency Plan for larger schemes; greenfield runoff or 50% attenuation; 16 m and 8 m set-backsEvidence on every source, the test position for the site, floor levels and a drainage statementA flood risk assessment that states which LP12 route the site is on, and a drainage strategy that tests greenfield firstWandsworth Local Plan 2023-2038, adopted 19 July 2023
Policy LP6Basements and Subterranean DevelopmentsOne storey only; no more than half the garden; 1 m of soil and a 200 mm drainage layer above; no added flood risk; a positive pumped device against sewer floodingA basement that passes LP12's zone and breach rules and carries the drainage detailBreach hazard and groundwater checked for the basement, with the pumped device and soil layer coveredWandsworth Local Plan 2023-2038, adopted 19 July 2023
Policy LP58River CorridorsNo encroachment within 16 m of the tidal Thames or 8 m of other rivers, including culverted ones; no building on the foreshoreA layout that keeps clear of the bank and defencesThe set-back measured on the site plan and any constraint explained for the Environment AgencyWandsworth Local Plan 2023-2038, adopted 19 July 2023
London Plan Policy SI 12Flood risk managementFlood risk minimised and mitigated, residual risk addressed, space made for water, Thames Estuary 2100 measures supportedA residual risk case behind the Thames wallsBreach depth and hazard from the Level 2 SFRA carried into the assessmentLondon Plan 2021, March 2021
London Plan Policy SI 13Sustainable drainageAim for greenfield runoff, manage water close to source, green before grey, six-step hierarchy; impermeable surfacing normally resistedEvidence for each step skippedA drainage strategy that works down the hierarchy step by stepLondon Plan 2021, March 2021
Draft London Plan Policy GHR5Flood risk and drainage (draft, consultation closed 15 October 2026)No increase in surface water runoff; referable schemes aim for greenfield QBAR or 3 l/s/ha, whichever is higherNot yet a test; weight grows as the draft moves to examinationReferable schemes shown against the draft rate as well as SI 13Draft London Plan 2026, consulted 16 July to 15 October 2026

Requirements checked November 2026.

Policy LP12 (Water and Flooding): the borough's single flood and drainage policy

Policy LP12 asks every application in Wandsworth to show it avoids or reduces flooding from all sources and does not raise risk elsewhere. Part A states that "All planning applications will need to clearly demonstrate that the proposals avoid or reduce contributing to all sources of flooding, including fluvial, tidal, surface water, groundwater, flooding from sewers", allowing for climate change (Local Plan, pages 314 to 325). LP12 replaced Policies DMS 5 (Flood risk management) and DMS 6 (Sustainable Drainage Systems) of the 2016 Development Management Policies Document when the plan was adopted in July 2023, as the council's Local Flood Risk Management Strategy (version 3.0, August 2023) records.

Part D adds that where an assessment is needed, any loss of river flood storage within the 1 in 100 year plus climate change extent is replaced level for level and volume for volume, and in undefended tidal areas there is no increase in built footprint or ground levels.

Policy LP12 (Water and Flooding) part E: when the Sequential Test is already passed

Part E treats the Sequential Test as passed in four cases, and outside them the default area of search is the whole borough. The four are a site inside one of the Local Plan's Area Strategy areas (with a 400 m buffer around the town centre strategies at Balham, Clapham Junction and York Road/Winstanley, Putney, Tooting and Wandsworth Town); a Local Plan site allocation used for its allocated use; redevelopment of a single dwelling; and minor development, conversions and changes of use, other than to caravan, camping, chalet or park home sites.

The other Area Strategy areas are the Vauxhall Nine Elms Battersea Opportunity Area, the Roehampton Regeneration Area, the Wandle Valley and Wandsworth's Riverside. The supporting text explains why: there is not enough low-risk land for the borough's housing targets (para 15.37), so instead of a site search "development within these areas will need to meet the requirements of the Exception Test" on site (para 15.32). For an allocation, paragraph 15.34 says the same: "An Exception Test will still be required as part of an application".

Outside those cases LP12 sets the borough as the default search area unless a smaller one is justified as the SFRA describes. Chapter 18 of the NPPF now also ties the search to the area the development is expected to serve, so the borough boundary is the outer limit, not a starting point that only shrinks with argument. Our guides on the sequential and exception tests and on the surface water exemption cover the national side.

Policy LP12 (Water and Flooding) Table 15.1: floor levels, access and the Flood Emergency Plan

Table 15.1 fixes how high a building sits in each zone. In river flood areas of Zones 2 and 3a, floors go "a minimum of 300mm above the 1 in 100 inclusive of an allowance for climate change flood level"; in defended tidal areas "all sleeping accommodation must be located on finished floor levels above the appropriate extreme water level as advised by the Environment Agency". Safe access and egress must be at a Low Hazard rating, and self-contained residential basements are not permitted in Zones 2 or 3a.

Part C then asks for a Flood Emergency Plan in Zones 2 and 3 on "sites of 10 or more dwellings or 1000sqm of non-residential development or more, or on any other proposal where safe access/egress cannot be achieved". The plan covers warning, refuge and evacuation; paragraph 15.42 sets it alongside, not inside, the flood risk assessment.

Policy LP12 (Water and Flooding) part J: the Thames walls and the 16 m strip

Part J protects the defences. Development "should be set back 16 metres from the landward side of any tidal Thames flood defences", and 8 m from the top of the bank or the outer edge of the culvert on other main rivers, unless exceptional circumstances are evidenced and agreed by the Environment Agency. Schemes must also show how the defences can be raised in line with the Thames Estuary 2100 Plan, and culverting or building over culverts will not be supported, while de-culverting is encouraged. Works near a main river can also need a permit from the Environment Agency, which applicants arrange with the Agency directly.

How we meet LP12: our assessment opens by stating which part E route applies, or sets the area of search where none does. It then deals with every source, takes breach depth and hazard from the Level 2 SFRA for tidal sites, sets floor and threshold levels against the right water level, and measures the set-back. The drainage strategy beside it starts from greenfield runoff and records the evidence for each hierarchy step.

Policy LP6 (Basements and Subterranean Developments) and LP12's basement table

Basements carry the borough's tightest flood rules. Policy LP6 limits a basement to one storey and half the garden, and requires "a positive pumped device (or equivalent) to mitigate against the risk of sewer flooding" for every basement proposal, and LP12 (para 15.40) asks for it to be shown on the drawings for any basement with a waste outlet. LP12's Table 15.2 then rules by flood zone and by the SFRA's breach hazard band.

  • Flood Zone 3b. No basements, extensions, conversions to a more vulnerable use or self-contained units.
  • Tidal Zone 3a, moderate to extreme breach hazard. New basements for less vulnerable or water compatible uses only; a more vulnerable use only where an assessment shows the risk to life can be managed; no basement bedrooms and nothing self-contained.
  • Tidal Zone 3a, low or no breach hazard; tidal Zone 2. Residential basements may be accepted if they are not self-contained and, where it applies, the Exception Test is passed; access thresholds and stairs must reach the safe level unless a permanent fixed barrier protects sleeping space.
  • Surface water risk, any zone. Raised thresholds, storage or other SuDS; no basement in an area of high surface water risk without that mitigation.

Paragraph 15.39 asks the applicant to confirm with the council whether the site falls in a breach hazard area. How we meet it: we read the hazard band from the Level 2 SFRA at the basement footprint, add the groundwater evidence and the pumped device, and state whether the use proposed is one LP12 allows. Our article on basement and cellar conversions in a flood zone covers the national position.

Policy LP58 (River Corridors): the bank-side strip on the Wandle and Beverley Brook

Policy LP58 repeats the set-back for ecology as well as flood defence: development "should not encroach within a minimum of 16m (tidal Thames) or 8m (other rivers including those culverted) of the top of the riverbank", and nothing may encroach onto the foreshore. On a Wandle or Beverley Brook site we show the strip on the plans and record any reason it cannot be met.

London Plan Policy SI 12 (Flood risk management): residual risk behind the defences

Policy SI 12 of the London Plan 2021 asks that "flood risk is minimised and mitigated, and that residual risk is addressed", with space made for water and support for the Thames Estuary 2100 measures. In Wandsworth that clause carries weight because so much of Flood Zone 3 is defended: our assessment sets out what a breach would do to the site as well as what the map shows. Our note on residual flood risk explains the idea.

London Plan Policy SI 13 (Sustainable drainage): the hierarchy LP12 follows

Policy SI 13 says development "should aim to achieve greenfield run-off rates and ensure that surface water run-off is managed as close to its source as possible", preferring green features to grey ones, and part C adds that impermeable surfacing "should normally be resisted", front gardens and driveways included. LP12 part G is the local, stricter form of the same rule, with its 50% floor.

Wandsworth's Local Plan full review and the draft London Plan's proposed Policies GHR5 and GHR9

The council's current Local Development Scheme 2023-2028 (March 2025) programmes a full review of the Local Plan after the Partial Review, with an indicative Regulation 18 "Issues" consultation in autumn 2026 and adoption in summer 2028. No consultation on it had been published when we checked in November 2026, so LP12 applies as written; the Partial Review, adopted on 4 March 2026, left it untouched. The change on the horizon is regional. The Mayor's draft London Plan 2026 was out to consultation from 16 July to 15 October 2026 (Mayoral Decision MD3515). Its draft Policy GHR5 (Flood risk and drainage) at that consultation stage says proposals "should not increase surface-water runoff" and asks referable schemes to aim for greenfield QBAR "or 3l/s/Ha (whichever is higher)"; draft GHR9 deals with river corridors and defences. If adopted, the new plan would replace the 2021 Plan, SI 12 and SI 13 included; until then the 2021 policies apply.

Is your Wandsworth site in an Area Strategy area or a breach hazard band?

We will confirm whether LP12 treats your Sequential Test as passed, what the Exception Test needs and what the basement rules allow. Get a no-obligation, free quote. One of our experienced flood risk consultants will get back to you within 60 minutes.

Start a Quote

The Wandsworth SFRA: breach hazard, Flood Zone 3b and the Wandle model

The evidence behind LP12 is on the council's SFRA reports page. The Level 1 SFRA was prepared by AECOM in November 2020 jointly for Wandsworth and Merton. The Level 2 SFRA (AECOM, 5 December 2020) covers Wandsworth alone and holds the tidal breach modelling, with a Level 2 addendum of January 2022 and the council's 2022 Sequential Test report on the allocations.

  • Breach hazard bands. The Level 2 SFRA maps depth and hazard for a breach at the 2100 extreme water level, graded Moderate (dangerous for some), Significant (dangerous for most) and Extreme (dangerous for all). LP12's basement table keys directly to these bands.
  • Areas Benefiting from Defences. The Local Plan (para 15.35) treats tidal Flood Zone 3 along the Thames and the Wandle Delta as defended by the river walls and the Thames Barrier, so the risk there is residual: breach or overtopping.
  • Flood Zone 3b. The SFRA draws the functional floodplain from the 5% (1 in 20) modelled outline on the Wandle, Graveney and Beverley Brook, and for the Thames as land riverward of the tidal defences, excluding the Wandsworth Delta island. NPPF Annex F now normally uses a 3.3% (1 in 30) probability; the SFRA's 1 in 20 line is the borough's own, set before that change.
  • Where 3b reaches. The Local Plan notes that Flood Zone 3b is mainly confined within the banks of the Thames and Wandle, so its strict rules apply only where a scheme encroaches on the river.
  • Surface water. The Surface Water Management Plan (Metis, December 2021) divides the borough into seven hydrological catchments, the units the council's 2023 Section 19 report uses to trace where storm water went.

Because the breach bands decide what a basement or ground floor can be used for, we take them from the Level 2 maps at the site itself rather than relying on the national flood map, which shows the defended zone but not its depth. Our explainers on what an SFRA is for and Flood Zone 3b give the background, and the Unda flood risk map shows the national zones for any address.

Wandsworth's validation checklist and when each report is needed

Wandsworth's Local Validation Checklist (July 2026) sets the flood documents an application needs. Item 20, "Flood Risk Assessment (FRA) including Sequential Test and Flood Emergency Plans", asks for an assessment with "all applications for developments located within flood zones 2, 3a and 3b". The checklist has no separate drainage strategy item; drainage is asked for through LP12 itself.

Triggers from the July 2026 Local Validation Checklist, Policies LP12 and LP6, and NPPF Chapter 18
TriggerFlood risk assessmentSequential and Exception TestsDrainage and other documents
Householder extension or other minor work in Flood Zones 2, 3a or 3bYes (checklist item 20 covers all applications in Zones 2, 3a and 3b)Sequential Test not needed (minor development under LP12 E4; NPPF Policy F5); Exception Test only where national policy requires it for the useFloodplain storage and flow routes kept (LP12 G3)
New homes or other development in Zone 2 or 3a outside an Area Strategy area and not an allocationYesSequential Test across the borough by default, or a justified smaller area; Exception Test where the use and zone require it (LP12 Table 15.1, NPPF Policy F6)Flood Emergency Plan if 10+ dwellings, 1,000 m² non-residential, or no safe access (LP12 C)
Site in an Area Strategy area (or the 400 m town centre buffer) or a Local Plan allocationYesSequential Test treated as passed (LP12 E1, E2); Exception Test requirements still met on site (paras 15.32, 15.34)As above
Flood Zone 1 site of 1 ha or more; land the EA has notified as having critical drainage problems; land the SFRA shows at increased future risk; or a more vulnerable use on land at risk from other sourcesYes (checklist item 20)No Exception Test in Flood Zone 1; for surface-water-only risk, NPPF Policy F5 exempts a scheme shown to keep occupiers safe without raising risk elsewhereSustainable Drainage Statement if major
Major development anywhere (DMPO 2015: 10+ homes, 0.5 ha+ where numbers are unknown, 1,000 m² floorspace, or a 1 ha site)Where any trigger above appliesAs aboveSustainable Drainage Statement (LP12 Table 15.1); LLFA consulted; London Sustainable Drainage Proforma
Basement, basement extension or conversionYes in Zones 2 and 3; surface water risk addressed in any zoneException Test where national policy applies to the usePositive pumped device on drawings (LP6 A8, LP12 para 15.40); 1 m soil and 200 mm drainage layer under gardens (LP6 A5); breach hazard band confirmed (LP12 para 15.39)
Within 16 m of a tidal Thames defence or 8 m of another main river (incl. culverted)Yes where in a flood zoneAs aboveSet-back or EA-agreed justification (LP12 J3, LP58 C); EA consulted within 20 m of the bank

The third row is where a thin assessment comes back: a passed Sequential Test does not shorten the flood risk assessment. The Exception Test's safety half, floor levels, refuge and a Low Hazard route out, still has to be evidenced for the site. The national standing advice for planning authorities covers minor extensions in Zones 2 and 3 alongside these local rules.

How Chapter 18 of the August 2026 NPPF sits alongside LP12

Since 17 August 2026 flood risk sits in Chapter 18 of the National Planning Policy Framework. Policy F4 sets when a site-specific assessment is needed, F5 and F6 the Sequential and Exception Tests, and F8 points drainage towards the 2025 National Standards for sustainable drainage. LP12 was written to the earlier Framework, so we read its clauses with Chapter 18: where LP12 is stricter, as on greenfield runoff and basements, the local rule governs; where Chapter 18 has moved, as on the anticipated-catchment limit to the Sequential Test, the national wording is applied. The flood risk Planning Practice Guidance, which explains how those policies are applied, dates from its 17 September 2025 revision. Our NPPF guidance and advice page follows each change.

Tidal Thames, the Wandle and summer storms: flood risk across the borough

The River Thames forms the borough's northern edge and is tidal throughout. Its walls and the Thames Barrier hold back the tide, and the Environment Agency's Thames Estuary 2100 Plan gives both of Wandsworth's riverside units, Barnes and Kew (to Putney Bridge) and Wandsworth to Deptford, policy P5: further action to reduce flood risk. By 2050 defence owners are to work with the Environment Agency to raise defences where required, and neither unit has a riverside strategy yet. Unda's guide to the Thames Barrier explains how closures work.

The River Wandle crosses the borough from Earlsfield to its tidal mouth at the Wandle Delta, the River Graveney flows through Tooting to meet it, and Beverley Brook runs along the western edge by Putney and Roehampton. Surface water is the commoner cause of flooded homes. The council's Section 19 report (June 2023) on the storms of 12 and 25 July 2021 records 15 incidents affecting 33 properties, near Putney Common in the west and on the Diamond Estate in Battersea in the east, where the sewers were overwhelmed. Our area pages for Battersea and Putney tell the local story, the London overview covers the wider city, and the live river levels map shows the gauges.

Reports we prepare for applications to Wandsworth Council

A flood risk assessment, a sequential or exception test and a drainage strategy answer three separate questions for a Wandsworth application: is the site safe, should it be here, and where does the water go. Each is written to the LP12 clause it serves.

Our consultants are chartered, and every quote is a fixed fee. Reports for applications to Wandsworth Council come from Unda Consulting Limited, a CIWEM Business Partner.

Frequently asked questions

What does Wandsworth Policy LP12 (Water and Flooding) require from a planning application?

LP12, in the Wandsworth Local Plan adopted on 19 July 2023, asks every application to show it avoids or reduces flooding from all sources and does not increase risk elsewhere. It sets the Sequential and Exception Test position, floor levels and Low Hazard access by flood zone, a Flood Emergency Plan for larger schemes in Zones 2 and 3, basement limits by SFRA breach hazard, SuDS reaching greenfield runoff or at least 50% attenuation, and 16 m and 8 m set-backs from the Thames defences and other main rivers.

Is the Sequential Test automatically passed for sites in Battersea, Nine Elms or Putney?

Often, but not everywhere. LP12 part E treats it as passed inside the Local Plan's Area Strategy areas, including the Vauxhall Nine Elms Battersea Opportunity Area and a 400 m buffer around Putney and the other town centre strategies, and on site allocations used as allocated. The Exception Test's requirements still have to be met on site, and a site outside those areas is searched across the borough unless a smaller area is justified.

Can I build a basement bedroom in a Wandsworth flood zone?

Not in Flood Zone 3b, and not in tidal Flood Zone 3a where the SFRA shows moderate, significant or extreme breach hazard. In lower-hazard tidal areas a residential basement may be accepted if it is not self-contained and access reaches the safe level. Every new basement also needs a positive pumped device under Policy LP6, shown on the drawings.

How far must a Wandsworth scheme cut its surface water runoff?

Greenfield runoff. LP12 part G asks for a reduction to greenfield rates unless that is shown to be technically unfeasible, and then at least 50% attenuation of the site's existing peak runoff, aiming for 100%. Surface water must not go to the foul sewer, and a connection to a public sewer needs written confirmation of capacity.

When does a Wandsworth scheme need a Sustainable Drainage Statement on top of its flood evidence?

For major development, yes: LP12 Table 15.1 requires a Sustainable Drainage Statement, and the council as Lead Local Flood Authority is consulted on the drainage. The July 2026 validation checklist asks for a flood risk assessment in Flood Zones 2, 3a and 3b and for some Flood Zone 1 sites, but has no separate drainage item, so smaller schemes deal with drainage inside the assessment.

Which SFRA does Wandsworth use, and is it up to date?

The Level 1 SFRA prepared by AECOM in November 2020 jointly with Merton, the Wandsworth Level 2 SFRA of 5 December 2020 with its breach hazard mapping, and a Level 2 addendum of January 2022. No update was in preparation when we checked in November 2026. Its Flood Zone 3b uses the older 1 in 20 year outline, where national guidance now normally uses 1 in 30.

Submitting to Wandsworth with a basement, a riverside plot or a major scheme?

We set out the LP12 route, the breach hazard and the drainage rate before the application goes in. Get a no-obligation, free quote, with a fixed quote within the hour.

Start a Quote

To talk through a Wandsworth site, call 01293 214444 or email enquiries@unda.co.uk. The full list of council pages is on our local authorities hub.

Get a no-obligation, free quote

If you need a quote or to discuss your requirements in more detail contact one of our experienced Flood Risk and Drainage Consultants.

Call +44 (0) 1293 214444, email enquiries@unda.co.uk or fill in the form below

  • This field is for validation purposes and should be left unchanged.